LINITHERM PAL GK - The insulation booster under the rafters or collar beams with existing between-rafter insulation

If the roofing is still intact, you don’t have to give up on the benefits of optimum roof insulation. LINITHERM PAL GK is simply screwed onto the underside of rafters or collar beamsor onto cladding. An intact between-rafter insulation remains in place. Skim, paint or wallpaper—done. The warm wall surfaces prevent otherwise commonly occurring draughts.

In perfect professional quality

  • With integral vapour barrier
  • Plasterboard facing on the inner side
  • LINITHERM PAL GKL with additional integral battens to compensate for irregularities of the roof structure
  • Full-surface, seamless insulation
  • Interior surface can be plastered and wallpapered

For PUR(E) energy saving

  • Insulating core made of PU rigid foam
  • λD 0.022 W/(mK)
  • Positive building biology

Below-rafter insulation - LINITHERM PAL GK

Insulation core: PU rigid foam acc. to EN 13165, fire behaviour class E acc. to EN 13501-1, coated with aluminum film on both sides
Facing: plasterboard facing on the inner side, 9.5 mm thick
Edge joints: round abour grooved for wooden tongue (included in delivery)
Outside dimensions: 2500 x 600 mm (= invoicing measurement)
λD (EN 13165): 0.022 W/(mK)
Thickness mm 39.5 49.5 69.5 89.5 109.5
U-value1) W/(m²K) 0.65 0.50 0.34 0.26 0.21
Other thicknesses on request.


Below-rafter insulation - LINITHERM PAL GKL

Same as LINITHERM GK, but with additional integral battens to compensate for irregularities of the roof structure
Insulation core: PU rigid foam acc. to EN 13165, fire behaviour class E acc. to EN 13501-1, coated with aluminum film on both sides
Facing: plasterboard facing on the inner side, 9.5 mm thick
System: with integrated battens for compensating unevenness in the roof structure during installation with adjusting screws (no additional slat framework required)
Edge joints: round abour grooved for wooden tongue (included in delivery)
Outside dimensions: 2500 x 600 mm (= invoicing measurement)
λD (EN 13165): 0.022 W/(mK)
Thickness mm 49.5 69.5
U-value1) W/(m²K) 0.55 0.37
Other thicknesses on request.
1) U-value, taking the thermal transfer resistance Rsi = 0.1 [m²K/W] and Rse = 0.04 [m²K/W] into account. Building-specific peculiarities for example as per EN ISO 6946 are not taken into account.
Wir benutzen Cookies um für Sie eine möglichst komfortable Bedienung und Funktionalität zu gewährleisten. Wenn Sie ohne Änderung Ihrer Einstellungen fortfahren, gehen wir davon aus, dass Sie damit einverstanden sind, alle Cookies von unserer Website zu empfangen. Diese Einstellungen können Sie jederzeit ändern. Weitere Informationen.