If it cannot be done from the outside, LINITHERM PAL SIL offers a well thought out complete programme. This highly effective protection against the cold, heat, moisture and mildew is the ideal candidate for: listed and intact facades, facades where exterior insulation is problematic due to structure heights and/or visual reasons, sporadically heated rooms, cellars to be converted into living space, etc.
In perfect professional quality
- Safe construction in terms of building physics
- Silicate panel bonded on
- Can be plastered, painted, and wallpapered
- With integral vapour barrier
- Low structural height
- Full-surface, seamless insulation for continuous installation
For PUR(E) energy saving
- Insulating core made of PU rigid foam
- λD 0.022 W/(mK)
- Positive building biology
Insulation for outside walls - LINITHERM PAL SIL
Insulation core |
PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1, coated with aluminum film on both sides |
Facing |
Silicate panel on room side, thickness 6 mm |
Edge joints |
Round about grooved for loose plywood spring (included in delivery), silicate panel with drywall edge |
Overall dimension |
2500 × 600 mm (= calculation measurement) |
λD (EN 13165) |
0.022 W/(mK) |
Thickness mm |
36 |
46 |
66 |
U-value1) W/(m²K) |
0.64 |
0.50 |
0.34 |
Insulation for outside walls - LINITHERM PAL SIL cutting board
Insulation core |
PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1, coated with aluminum film on both sides |
Facing |
Silicate panel on room side, thickness 6 mm |
Edge joints |
Untrimmed |
Overall dimension |
2500 × 1200 mm (= calculation measurement), reveal board without edge connection |
λD (EN 13165) |
0.022 W/(mK) |
Thickness mm |
26 |
U-value1) W/(m²K) |
0.91 |
Insulation for outside walls - LINITHERM PAL SIL L - for walls that will be tiled or under flat roofs
Insulation core |
PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1, coated with aluminum film on both sides |
System |
With integrated battens for mechanical fixation |
Facing |
Silicate panel on room side, thickness 6 mm, affixed to the integrated battens with clips |
Edge joints |
Round about grooved for loose plywood spring (included in delivery), silicate panel with drywall edge |
Overall dimension |
2500 × 600 mm (= calculation measurement) |
λD (EN 13165): |
0.022 W/(mK) |
Thickness mm |
46 |
66 |
U-value1) W/(m²K) |
0.55 |
0.37 |
Insulation for outside walls - LINITHERM PAL SIL COIGN
Insulation core: |
PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1 |
System |
With integrated battens for mechanical fixation |
Facing |
Silicate panel on room side, thickness 6 mm, affixed to the integrated battens with clips |
Edge joints |
Round about edgeless cut |
Overall dimension |
2500 × 600 mm (= calculation measurement) |
λD (EN 13165): |
0.028 W/(mK) |
Thickness mm total |
Thickness mm PU |
Thickness mm silicate panel |
66/6 |
60/0 |
6 |
Insulation for outside walls - LINITHERM PAL SIL REVEAL COIGN
Insulation core: |
PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1 |
Facing |
Silicate panel on room side, thickness 6 mm |
Edge joints |
Round about edgeless cut |
Overall dimension |
2500 × 300 mm (= calculation measurement) |
λD (EN 13165): |
0.028 W/(mK) |
Thickness mm total |
Thickness mm PU |
Thickness mm silicate panel |
26/14 |
20/8 |
6 |
1) U-value, taking the thermal transfer resistance Rsi = 0.13 [m²K/W] and Rse = 0.04 [m²K/W] into account. Building-specific characteristics for example as per EN ISO 6946 are not taken into account.