English

LINITHERM PAL SIL - Space-saving insulation so that mildew doesn’t stand a chance

If it cannot be done from the outside, LINITHERM PAL SIL offers a well thought out complete programme. This highly effective protection against the cold, heat, moisture and mildew is the ideal candidate for: listed and intact facades, facades where exterior insulation is problematic due to structure heights and/or visual reasons, sporadically heated rooms, cellars to be converted into living space, etc.

In perfect professional quality

  • Safe construction in terms of building physics
  • Silicate panel bonded on
  • Can be plastered, painted, and wallpapered
  • With integral vapour barrier
  • Low structural height
  • Full-surface, seamless insulation for continuous installation

For PUR(E) energy saving

  • Insulating core made of PU rigid foam
  • λD 0.022 W/(mK)
  • Positive building biology

Insulation for outside walls - LINITHERM PAL SIL

Insulation core PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1, coated with aluminum film on both sides
Facing Silicate panel on room side, thickness 6 mm
Edge joints Round about grooved for wooden tongue (included in delivery), silicate panel with drywall edge
Coverage 2500 x 600 mm (= invoicing measurement)
λD (EN 13165) 0.022 W/(mK)
Thickness mm 36 46 66
U-value1) W/(m²K) 0.64 0.50 0.34

Insulation for outside walls - LINITHERM PAL SIL cutting board

Insulation core PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1, coated with aluminum film on both sides
Facing Silicate panel on room side, thickness 6 mm
Edge joints Untrimmed
Coverage 2500 x 1200 mm (= invoicing measurement), reveal board without edge connection
λD (EN 13165) 0.022 W/(mK)
Thickness mm 26
U-value1) W/(m²K) 0.91

Insulation for outside walls - LINITHERM PAL SIL L - for walls that will be tiled or under flat roofs

Insulation core: PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1, coated with aluminum film on both sides
System: with integrated battens for mechanical fixation
Facing: silicate panel on room side, thickness 6 mm, affixed to the integrated battens with clips
Edge joints: round about grooved for wooden tongue (included in delivery), silicate panel with drywall edge
Coverage: 2500 x 600 mm (= invoicing measurement)
λD (EN 13165): 0.022 W/(mK)
Thickness mm 46 66
U-value1) W/(m²K) 0.55 0.37

Insulation for outside walls - LINITHERM PAL SIL COIGN

Insulation core: PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1
System: with integrated battens for mechanical fixation
Facing: silicate panel on room side, thickness 6 mm, affixed to the integrated battens with clips
Edge joints: round about edgeless cut
Coverage: 2500 x 600 mm (= invoicing measurement)
λD (EN 13165): 0.028 W/(mK)
Thickness mm total Thickness mm PU Thickness mm silicate panel
66/6 60/0 6

Insulation for outside walls - LINITHERM PAL SIL REVEAL COIGN

Insulation core: PU rigid foam acc. to EN 13165, fire behavior class E acc. to EN 13501-1
Facing: silicate panel on room side, thickness 6 mm
Edge joints: round about edgeless cut
Coverage: 2500 x 300 mm (= invoicing measurement)
λD (EN 13165): 0.028 W/(mK)
Thickness mm total Thickness mm PU Thickness mm silicate panel
26/14 20/8 6
1) U-value, taking the thermal transfer resistance Rsi = 0.13 [m²K/W] and Rse = 0.04 [m²K/W] into account. Building-specific peculiarities for example as per EN ISO 6946 are not taken into account.
Wir benutzen Cookies um für Sie eine möglichst komfortable Bedienung und Funktionalität zu gewährleisten. Wenn Sie ohne Änderung Ihrer Einstellungen fortfahren, gehen wir davon aus, dass Sie damit einverstanden sind, alle Cookies von unserer Website zu empfangen. Diese Einstellungen können Sie jederzeit ändern. Weitere Informationen.